100% Outdoor Air Duct MVD D4+

TECHNICAL SPECIFICATIONS

ModelMVD-D125T1/N1-FAMVD-D140T1/N1-FAMVD-D200T1/N1-FAMVD-D250T1/N1-FAMVD-D280T1/N1-FA
CodeCL23190CL23191CL23192CL23193CL23194
Electrical PowerF, V, Hz1N-, 220-240, 501N-, 220-240, 501N-, 220-240, 501N-, 220-240, 501N-, 220-240, 50
Cooling (1)CapacitykW12,514202528
Power ConsumptionW430430200021262126
IntensityA2,42,45,35,65,6
Heating (2)CapacitykW10,512182022
Power ConsumptionW430430200021262126
IntensityA2,42,45,35,65,6
FanBrandYong AnYong AnYong AnYong AnYong An
TypeACACACACAC
Quantity11222
ModelYSK300-4C-1YSK300-4C-1YDK250-4XYDK250-4XYDK250-4X
Flow Rate (High / Medium / Low)m³/h2142 / 1870 / 16112142 / 1870 / 16112870 / 2620 / 21503005 / 2700 / 22503005 / 2700 / 2250
Sound Level (High / Medium / Low) (3)dB(A)54 / 52 / 5054 / 52 / 5054 / 53 / 5155 / 54 / 5255 / 54 / 52
Static PressurePa50 (50-196)50 (50-196)200 (50-280)200 (50-280)200 (50-280)
PowerW430430100010631063
Indoor UnitDimensionsNet (W x H x D)mm1300 x 420 x 6901300 x 420 x 6901443 x 470 x 8101443 x 470 x 8101443 x 470 x 810
Gross (W x H x D)mm1436 x 450 x 7681436 x 450 x 7681509 x 550 x 9901509 x 550 x 9901509 x 550 x 990
WeightNetKg69,569,5115115115
GrossKg7676125125125
DrainageConnectionmm3232323232
RefrigerantTypeR410AR410AR410AR410AR410A
Design PressureHighMpa4,44,44,44,44,4
LowMpa2,62,62,62,62,6
Refrigerant ConnectionsLiquidmm (“)9,52 (3/8)9,52 (3/8)9.52 (3/8) x 29.52 (3/8) x 29.52 (3/8) x 2
Gasmm (“)15,9 (5/8)15,9 (5/8)15.9 (5/8) x 215.9 (5/8) x 215.9 (5/8) x 2
Electrical Connections (4)Powermm22 x 2.5 + T (L<20m)2 x 2.5 + T (L<20m)2 x 2.5 + T (L<20m)2 x 2.5 + T (L<20m)2 x 2.5 + T (L<20m)
Signalmm23 x 0.75 (Shielded)3 x 0.75 (Shielded)3 x 0.75 (Shielded)3 x 0.75 (Shielded)3 x 0.75 (Shielded)
Remote controlModelKJR-29BKJR-29BKJR-29BKJR-29BKJR-29B
TypeWiringWiringWiringWiringWiring

Notes:

(1) Nominal cooling conditions: outdoor 33ºC DB and 24ºC WB, for an equivalent pipe length of 8 m and height difference of 0 m.

(2) Nominal heating conditions: outdoor 0ºC DB and -1ºC WB, for an equivalent pipe length of 8 m and height difference of 0 m.

(3) Sound level measured in an anechoic chamber at a frontal distance of 1m and a height of 1.4m.

(4) Recommended power wiring for L < 20m, for longer distances it must be calculated.

Characteristics

  • Digital LED display
  • 100% Outdoor Air
  • Static pressure up to 280 Pa
  • Wired remote control included

Technical documentation

User Manual EN EN
Installation Manual EN
Technical Manual EN