MUP-W9 Series

MUP-W9 Series Wall Fan Coil Unit

TECHNICAL SPECIFICATIONS

ModelMUP-09-W9MUP-12-W9MUP-16-W9MUP-18-W9
CodeCL04325CL04326CL04327CL04328
Cooling (1)Capacity (High / Medium / Low)kW2,7 / 2,59 / 2,393,81 / 3,3 / 2,884,47 / 3,98 / 3,484,87 / 4,26 / 3,79
Water flow (High / Medium / Low)m 3 /h0,48 / 0,46 / 0,420,67 / 0,57 / 0,510,77 / 0,68 / 0,610,85 / 0,72 / 0,65
Pressure drop (High / Medium / Low)kPa31,61 / 28,63 / 25,3656,75 / 41,23 / 33,0241,17 / 33,54 / 27,0550,68 / 39,47 / 33,66
Consumption (High / Medium / Low)W13 / 11 / 1034 / 22 / 1526 / 18 / 1338 / 26 / 18
Heating45ºC (2)Capacity (High / Medium / Low)kW3,02 / 2,85 / 2,354,3 / 3,65 / 3,094,84 / 4,23 / 3,625,26 / 4,68 / 3,96
Water flow (High / Medium / Low)m 3 /h0,51 / 0,49 / 0,460,73 / 0,64 / 0,560,84 / 0,73 / 0,640,89 / 0,80 / 0,68
Pressure drop (High / Medium / Low)kPa32,66 / 34,89 / 30,2451,86 / 47,53 / 35,6936,82 / 33,83 / 26,2647,12 / 42,75 / 32,95
Consumption (High / Medium / Low)W11 / 11 / 931 / 20 / 1422 / 16 / 1233 / 23 / 16
50ºC (3)Capacity (High / Medium / Low)kW3,29 / 3,03/ 2,635,08 / 4,33 / 3,775,68 / 4,94 / 4,246,31 / 5,57 / 4,77
Water flow (High / Medium / Low)m 3 /h0,48 / 0,46 / 0,420,67 / 0,57 / 0,510,77 / 0,68 / 0,610,85 / 0,72 / 0,65
Pressure drop (High / Medium / Low)kPa37,49 / 30,25 / 26,5361,94 / 37,88 / 30,3443,74 / 29,69 / 23,9851,65 / 36,3 / 30,3
Consumption (High / Medium / Low)W12 / 10 / 831 / 20 / 1423 / 16 / 1233 / 23 / 16
Air flow (High / Medium / Low)m 3 /h492 / 454 / 400825 / 869 / 590862 / 741 / 634979 / 849 / 717
Heat exchanger water volumeL0.7330.7331.0271.027
Power supplyV / F / Hz220-240 / 1 / 50220-240 / 1 / 50220-240 / 1 / 50220-240 / 1 / 50
Sound pressure (High / Medium / Low) (4)dB(A)32 / 30 / 2745 / 39 / 3538 / 34 / 3044 / 40 / 35
Max. operating pressureMPa1.61.61.61.6
Water connectionsinch3/4″3/4″3/4″3/4″
Drain connectionmmΦ20Φ20Φ20Φ20
Dimensions (Width x Height x Depth)mm915 × 290 × 233915 × 290 × 2331072 × 315 × 2371072 × 315 × 237
Weightkg12.712.715.114.9

Notes:

(1) Cooling capacity for each of the 3 air flows and according to conditions: Water inlet/outlet temp. 7/12ºC, Ambient temp. 27ºC DB, 19ºC WB.
(2) Heating capacity for each of the 3 air flows and according to conditions: Water inlet/outlet temp. 45/40ºC, Ambient temp. 20ºC.
(3) Heating capacity for each of the 3 air flows and according to conditions: Water inlet temp. 50ºC, Ambient temp. 20ºC (for other temperatures see the
technical manual).
(4) Sound pressure level measured in a reverberation chamber, 1m away from the equipment both horizontally and vertically.
– The design and specifications are subject to change without prior notice for product improvement.

Characteristics

  • 2-pipe wall-mounted fan coil unit.
  • 3-way valve with by-pass included.
  • DC fan motor with 3 speeds.
  • 0-10V input for speed selection.
  • 0-10V output for the control of an auxiliary 0-10V valve.
  • Automatic fin oscillation.
  • Digital display with the possibility of turning it off (only via the RM12F control).
  • Remote ON/OFF signal.
  • Easily reversible hydraulic connections (left/right)
  • Possibility of modifying the compensation temperature.
  • Possibility of connection to CCM centralized control.
  • Integrated Modbus (RTU) communication.
  • Remote control not included, RM12F recommended (CL97820).

Technical documentation

Technical Data Sheet ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18
User and Installation Manual ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18
Technical Manual EN 18X18