MVD V8m Series
The new V8M series allows the connection of up to 200% of the outdoor unit capacity.
High Static Pressure
The available static fan pressure can be increased up to 80 Pa.
Scroll Compressor Dc Inverter Evi (Enhanced Vapor Injection)
The EVI compressor increases refrigerant circulation and improves capacity in both cooling and heating.
2-Stage Subcooling
Increases refrigerant subcooling, resulting in a 10% improvement in energy efficiency and a reduction in refrigerant flow noise.
Energy Management System
For projects with temporary power supply restrictions, the V8M series can be configured to limit its capacity between 40 ~ 100% in
1% steps
Incorporates Bluetooth Module
For easier start-up and maintenance, the V8M series allows you to configure and query operating parameters via mobile phone, using the LET’S THINK application.
Low Stand-By Consumption
The V8M series only consumes 3.5 W in stand-by mode, compared to an average of 30 W in a conventional VRF.
Double “Backup” Function
01 – Fans
The equipment can be left running with only one fan.
02 – Sensors
Even if a temperature sensor fails, the equipment can continue to operate, thanks to the algorithm that allows generating a virtual sensor to operate as a backup.
Maintenance Mode
When maintenance mode is activated, the outdoor unit does not verify the number of indoor units connected, so the system can continue to operate without some of the indoor units.
Easy Installation
The mini MVD can be transported by forklift. Its small size greatly facilitates installation and effectively reduces
the time and personnel required.
Simplified Connection
The central control connects directly to the outdoor unit and automatic addressing is activated, so that the control detects all the indoor units connected to that outdoor unit. Later
we can modify the addresses manually with the individual control of each equipment.
Refrigerant Shortage/Excess Detection
The V8M series can detect a shortage or excess of refrigerant gas in the system.
Automatic Refrigerant Gas Charging
The V8M series allows the refrigerant gas to be charged to the system automatically without having to perform the additional charge calculation.
Floating Evaporation/Condensation Temperature
The evaporation temperature (in cooling) and the condensation temperature (in heating) are automatically adjusted according to the indoor and outdoor temperature to balance comfort and energy efficiency.
Maximum Pipe Length
The Mini MVD V8M system supports a maximum pipe length of 150m, with a height difference between the outdoor unit and the indoor units of up to 50m.
Automatic Addressing
By default, the first time power is supplied to the entire system, the outdoor unit assigns the address to each indoor unit automatically. Later, the address of each indoor unit can be consulted and modified from its local control.