TECHNICAL SPECIFICATIONS

ModelMUC-12-HP4MUC-16-HP4MUC-25-HP4MUC-31-HP4MUC-43-HP4MUC-54-HP4MUC-68-HP4
CodeCL04571CL04572CL04573CL04574CL04575CL04576CL04577
Air
flow
Heightm3/h6801.0201.3601.7002.3803.0604.080
Mediumm3/h5107951.0201.2751.7852.2953.060
Lowm3/h3405106808501.1901.5302.010
Total cooling capacityHighkW3,74,97,59,312,815,920,1
MediumkW3,04,06,17,510,412,916,3
LowkW2,22,94,55,67,79,512,1
Sensible cooling capacityHighkW2,63,65,46,69,111,514,6
MediumkW2,12,94,35,37,39,211,7
LowkW1,52,13,23,95,46,88,6
Heating capacityHighkW5,57,511,313,919,124,230,7
MediumkW4,45,98,911,015,119,224,3
LowkW3,04,26,37,710,613,417,0
Water flowm3/h0,6360,8461,3021,6082,2022,7363,456
Pressure dropkPa13,622,910,815,732,1911,1
ConsumptionA0,40,70,91,21,52,23,3
Static pressurePa626281103117132122
Hydraulic connection3/4″3/4″3/4″3/4″3/4″3/4″3/4″
Dimensions(L x W x H)mm500 x 825 x 260500 x 825 x 260550 x 1,000 x 315550 x 1,000 x 315650 x 1,200 x 315620 x 1,400 x 350670 x 1,400 x 400
Sound pressuredB(A)44475252606266

Observations:

1. Cooling: Interior Temp. 27°C DB 19.5°C WB. Water temp 7-12°C
2. Heating: Ambient Temp. 21°C. Water temp. 70-60°C

Characteristics

  • High static pressure
  • Built in galvanized steel
  • 3-speed fan motor
  • 3-5mm thick filter