MUPR-H7 Series

Wall Split MUPR-H7 Series (R32 Refrigerant)

SAVE INSTALLATION TIME

Easily Removable

Easy access to the PCB, removable fan, movable casing.

Reduces maintenance time by 30%.

More Space for Installation

New support, retaining clips, simpler electrical connection.

20% saving in installation time.

More Accessible Filters

No need to open the panel, avoids dirt falling.

Saves 5% in cleaning time.

Extensive Connectivity

Possibility of connecting different control devices, including a WIFI module.

Control your new Mundoclima air conditioner from anywhere.

“Follow Me” Function

The wireless remote control incorporates a temperature sensor.

Automatic Restart

Recovery of settings prior to power failure.

Emergency Operation

Possibility of operating the unit with the manual button in the event of some alarms.

Cold Air Prevention

In heating, the initial fan speed is adjusted according to the battery temperature.

Turbo Operation

Reduction of Cooling/Heating time to the maximum.

Fewer Screws

Both the indoor and outdoor units have fewer screws, making disassembly much easier.

Low Noise Level

Thanks to the Silence mode and its new design, the noise level in the indoor unit is reduced to a minimum of 22dB (in the MUPR-09-H7 mode). In the outdoor unit, optimized design of the air outlet grille with a noise reduction of 3.3 dB(A) compared to previous models.

Adjustment of the Setpoint Temperature Range

The new remote control allows you to adjust: Minimum cooling from 17ºC to 24ºC; Maximum heating from 30ºC to 25ºC.

Refrigerant leak detection

Refrigerant Leak Detection

The unit automatically detects the existence of possible refrigerant leaks in the circuit.

Several Indoor Fan Speeds

Up to 12 fan speed levels of the indoor unit that are automatically adjusted if automatic ventilation is activated.

Self-cleaning

This function cleans the interior battery, keeping the equipment dry and preventing bacteria from forming.

8ºc Heating

This function ensures that the ambient temperature in winter will never be below 8ºC while we are not at home.

3 night modes

Night Mode

This function allows the equipment to automatically increase the temperature in cooling or decrease the temperature in heating 1ºC per hour during the first 2 hours, and then keep it constant for the next 5 hours and finally turn off. This function saves energy and provides comfort during the night.

icona-refrigeracion-temperaturas-bajas

Cooling in Low Temperatures

Cooling operation down to -15ºC outdoors.

icona-compensacion-temperatura

Temperature Compensation

The new remote control allows you to adjust the compensation temperature for the heating mode.

Multiple Outdoor Fan Speeds

Precise adjustment of the fan speed thanks to the DC motor.

Stanby function (only 1w)

Standby Function (Only 1w in Standby)

The outdoor unit is automatically disconnected from the power supply when the unit is in standby, so the standby consumption is only 1W.

Wide Operating Range

Cooling operation up to 50ºC and heating down to -15ºC.

Cold Catalyst Filter

U-shaped Legs

Thanks to the new rear legs of the outdoor unit, installation is more comfortable (except in MUPR-18-H7).

WIFI Module (Optional)

Possibility of connecting a WIFI module to control the equipment from anywhere with a SmartPhone.

TECHNICAL SPECIFICATIONS

ModelMUPR-09-H7MUPR-12-H7MUPR-18-H7MUPR-24-H7
CodeCL20035CL20036CL20037CL20038
RefrigerationNominal capacity (min ~ max)kW2,63 (1,20 – 3,42)3,51 (1,40 – 4,57)5,27 (1,96 – 6,21)7,32 (3,04 – 8,44)
Nominal consumption (min ~ max)kW0,77 (0,10 – 1,32)1,25 (0,11 – 1,74)1,50 (0,15 – 2,22)2,26 (0,23 – 3,01)
Pdesignc (design load)kW2,63,55,37,3
SEERW/W6,86,57,16,9
Energy LabelingA++A++A++A++
HeatingNominal capacity (min ~ max)kW2,93 (0,82 – 3,86)4,10 (0,87 – 5,12)5,56 (1,28 – 6,97)7,61 (2,08 – 9,43)
Nominal consumption (min ~ max)kW0,78 (0,14 – 1,38)1,17 (0,15 – 1,83)1,39 (0,22 – 2,33)2,11 (0,33 – 3,15)
Intermediate climate zonePdesignh (design load)kW2,42,54,25,6
SCOPW/W4444
Energy labelA+A+A+A+
Tbiv (Bivalent temperature)ºC-7-7-6-7
Warm climate zonePdesignh (design load)kW33,24,57
SCOPW/W5,15,25,15,1
Energy labelA+++A+++A+++A+++
Tbiv (Bivalent temperature)ºC2222
Tol (Operating limit temperature)ºC-15-15-15-15
Electrical PowerV-Hz-F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F
Maximum consumptionkW2,0752,22,553,6
Maximum intensityA9,51011,516
Indoor UnitAir flow (High / Medium / Low)m3/h486 / 433 / 329550 / 490 / 360810 / 720 / 5501050 / 970 / 650
Sound pressure (High / Medium / Low / Silence)dB(A)41 / 34 / 29 / 2241 / 37 / 30 / 2345 / 41 / 33 / 2446 / 44 / 35 / 27
Sound power (High)dB(A)53545759
Dimensions (W x H x D)mm717 x 302 x 193805 x 302 x 193964 x 325 x 2221106 x 342 x 232
WeightKg7,58,210,814,3
Outdoor UnitAir flow (max)m3/h2000200021002700
Sound pressure (High)dB(A)55555759
Sound power (High)dB(A)58606065
Dimensions (W x H x D)mm770 x 555 x 300770 x 555 x 300800 x 554 x 333845 x 702 x 363
WeightKg26,426,53748
RefrigerantTypeR32R32R32R32
LoadKg0,70,81,251,6
Precharge up tom5555
Additional charge (from 5m)g/m12121224
Refrigerant pipesLiquidmm(inch)6.35 (1/4″)6.35 (1/4″)6.35 (1/4″)9.52 (3/8″)
Gasmm(inch)9.52 (3/8″)9.52 (3/8″)12.7 (1/2″)15.9 (5/8″)
Maximum lengthm25253050
Maximum height differencem10102025
Electrical WiringPower supply (outdoor unit)mm22 x 2.5 + T2 x 2.5 + T2 x 2.5 + T2 x 4 + T
Interconnectionmm24 x 2.5 + T4 x 2.5 + T4 x 2.5 + T4 x 4 + T
Wireless Remote ControlRG57RG57RG57RG57
Operating temperatureIndoor (Cooling / Heating)ºC17 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 30
Outdoor (Cooling / Heating)ºC-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30
Warning:
1. Data and Specifications are Subject to Change without Notice.
2. The Sound Level Values Correspond to the Values Obtained in the Anechoic Chamber.

PRE-INSTALLATION REQUIREMENTS

MODELPIPINGELECTRICAL CONNECTIONS
GasLiquidMaximum length (B)Maximum height difference (A)Precharge up toAdditional chargePower supply (D)Interconnection (C)
MUPR-09-H73/8″1/4″25 m10 m5 m12 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-12-H73/8″1/4″25 m10 m5 m12 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-18-H71/2″1/4″30 m20 m5 m12 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-24-H75/8″3/8″50 m25 m5 m24 gr/m2 x 4 + T4 x 4 + T

OPTIONAL

DESCRIPTIONCODE
Wifi ModuleCL94382
Wall Control KJR-12BCL92905
Multi-Function Module, incorporates:– Remote ON/OFF signalCL94383
– Remote alarm signal
– Wall control connection with weekly programmer (KJR-120C)
– CCM centralized control connection
Wall Control with Weekly Programmer KJR-120C*CL94384
Centralized Control*CCM03/E(M)CL92911
CCM30/BKE-BCL92871
Warning:
* to Connect it, the Multi-Function Module (CL94383) is Necessary

Characteristics

  • More ecological thanks to R32 refrigerant
  • “Follow Me” function
  • Automatic restart
  • Emergency operation
  • Cold air prevention
  • Turbo operation
  • Low noise level
  • Temperature compensation
  • Multiple outdoor fan speeds
  • Fewer screws
  • Low temperature cooling
  • Standby Function (1W)
  • Refrigerant leak detection
  • Adjustment of the setpoint temperature range
  • Several indoor fan speeds
  • Self-cleaning
  • U-shaped legs
  • Wide operating range
  • Night Mode
  • 8ºC Heating
  • WIFI module (optional)

Technical documentation

Technical Data Sheet ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18
User and Installation Manual ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18
Technical Manual EN 18X18
Functions Adjustment Manual ES 18X18 EN 18X18 FR 18X18
Wifi Module Manual ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18
Multi-Function Module Manual ES 18X18 EN 18X18
Wall Control Manual KJR-120C ES 18X18 EN 18X18 FR 18X18 FROM 18X18
Energy labels ES 18X18 EN 18X18 FR 18X18 FROM 18X18
Seasonal Performance Charts
CE declaration of conformity ES 18X18 EN 18X18 FR 18X18 FROM 18X18 PT 18X18

Energy efficiency