Wall Mounted MUPR-H4 Series
Turbo Operation
This function maximizes the heating or cooling effect. Thus, the environment cools down or heats up quickly, and the desired temperature is achieved in a short time.
Night Mode
This function allows the unit to increase (cooling) or decrease (heating) the ambient temperature by 1°C per hour for the first 2 hours. For the first 5 hours, the same temperature is maintained, then the unit turns off. The function guarantees an ideal temperature and energy saving.

Automatic Restart
If there is a power outage and the machine turns off, when the power returns, it automatically turns on with the last selected settings.

Emergency Operation
If there is an error in the temperature sensor, the air conditioning unit will display an error code and turn off immediately.

Smart Anti-Cold Function
When activating the heating mode, the fan speed automatically increases from the lowest level to the preset level, depending on the heating of the evaporator. This avoids the emission of initial cold air, which is uncomfortable for the user.

Wide Operating Range
Up to 25 compressor frequency levels (F1-F25), and a wider frequency range of 70%, as well as more accurate and concise control, guarantee more comfort and energy savings. Thanks to a modern technology that allows adjusting the frequency to the preheating of the compressor, the unit can operate in temperatures as low as -20°C.

Cold Catalyst Filter
Eliminates formaldehyde and other volatile organic compounds (VOCs), as well as harmful gases and odors.

Turbo Operation
This function maximizes the heating or cooling effect. Thus, the environment cools down or heats up quickly, and the desired temperature is achieved in the shortest possible time.

Refrigerant Leak Detection
Thanks to this new technology, the indoor unit emits an alarm if a refrigerant leak is detected in the outdoor unit.

Several Indoor Fan Speeds
Up to 12 fan speed levels of the indoor unit guarantee a pleasant air flow for more comfort and well-being.

Cooling in Low Temperatures
The air conditioning can operate at low temperatures and can be used for cooling in outdoor temperatures down to -15ºC.

Temperature Compensation
The indoor unit automatically compensates for temperature variations due to the height of the installation.

5 Outdoor Fan Speeds
Thanks to the DC fan motor, the number of speeds increases from 2 to 5. These speed levels guarantee greater well-being and energy savings.

Standby Function (Only 1w)
The intelligent ON/OFF technology allows energy saving in Standby mode. This allows reducing the
energy consumption from 4-5W to 1W, resulting in an energy saving of 80%.
TECHNICAL SPECIFICATIONS
| Model | MUPR-09-H4 | MUPR-12-H4 | MUPR-18-H4 | MUPR-24-H4 | ||
|---|---|---|---|---|---|---|
| Code | CL 20 805 | CL 20 806 | CL 20 807 | CL 20 808 | ||
| Refrigeration | Capacity | kW | 2,6 | 3,5 | 5,1 | 6,4 |
| Kcal/h | 2.236 | 3.010 | 4.386 | 5.504 | ||
| Consumption (min-max) | W | 822 (144-1.240) | 1.090 (139-1.650) | 1.593 (157-2.270) | 2.080 (204-2.730) | |
| Heating | Capacity | kW | 2,9 | 3,4 | 5,2 | 7,3 |
| Kcal/h | 2.494 | 2.924 | 4.472 | 6.279 | ||
| Consumption (min-max) | W | 794 (175-1.230) | 1.015 (177-1.620) | 1.455 (191-2.220) | 2.055 (293-3.090) | |
| SEER | W/W | 5,6 | 5,6 | 6,1 | 5,9 | |
| Energy Efficiency Class Cooling | A+ | A+ | A++ | A+ | ||
| SCOP | W/W | 3,8 | 3,8 | 3,8 | 3,8 | |
| Energy Efficiency Class Heating | A | A | A | A | ||
| Minimum operating temperature | ºC | -15 | -15 | -15 | -15 | |
| Indoor air flow (High/Medium/Low) | m³/h | 650/560/450 | 650/560/450 | 750/550/480 | 1.100/970/800 | |
| Indoor sound pressure (High/Medium/Low) | dB (A) | 40/38/31 | 43/39/31 | 44/34/32 | 50/47/40 | |
| Outdoor air flow (High) | m³/h | 1.800 | 1.800 | 2.200 | 2.700 | |
| Outdoor sound pressure (High) | dB (A) | 56 | 56 | 59 | 60 | |
| Net dimensions (mm) | Interior (W x D x H) | mm | 800 x 188 x 275 | 800 x 188 x 275 | 940 x 205 x 275 | 1,045 x 235 x 315 |
| Exterior (W x D x H) | mm | 780 x 250 x 540 | 780 x 250 x 540 | 760 x 285 x 590 | 845 x 320 x 700 | |
| Net weight | Interior | kg | 7,5 | 7,5 | 9 | 12,5 |
| Exterior | kg | 28 | 28 | 35 | 47 | |
| Refrigerant pipes | Liquid | inches | 1/4″ | 1/4″ | 1/4″ | 3/8″ |
| Gas | inches | 3/8″ | 3/8″ | 1/2″ | 5/8″ | |
Warning:
1. Data and Specifications are Subject to Change without Notice.
2. The Sound Level Values Correspond to the Values Obtained in the Anechoic Chamber.
PRE-INSTALLATION REQUIREMENTS
| MODEL | PIPING | ELECTRICAL CONNECTIONS | ||||||
|---|---|---|---|---|---|---|---|---|
| Gas | Liquid | Maximum length (B) | Maximum height difference (A) | Precharge up to | Additional charge | Power supply (D) | Interconnection (C) | |
| MUPR-09-H4 | 3/8″ | 1/4″ | 25 m | 10 m | 5 m | 15 gr/m | 2 x 2.5 + T | 4 x 2.5 + T |
| MUPR-12-H4 | 3/8″ | 1/4″ | 25 m | 10 m | 5 m | 15 gr/m | 2 x 2.5 + T | 4 x 2.5 + T |
| MUPR-18-H4 | 1/2″ | 1/4″ | 30 m | 20 m | 5 m | 15 gr/m | 2 x 4 + T | 4 x 4 + T |