Wall Split MUPR-H5A Series
Energy Label a++ / a+
SEER 6.1 / SCOP 4.0
Hidden LED Display
The indicator light is hidden under the front panel, so the temperature and error codes are displayed in a more elegant way.

Automatic Restart
Recovery of settings prior to power failure.

Cold Air Prevention
In heating, the initial fan speed is adjusted according to the battery temperature.

Standby Function (Only 1w in Standby)
The outdoor unit is automatically disconnected from the power supply when the unit is in standby, so the standby consumption is only 1W.

Emergency Operation
Possibility of operating the unit with the manual button in the event of some alarms.

Turbo Operation
Reduction of Cooling/Heating time to the maximum.

Wide Operating Range
Cooling operation up to 50ºC and heating down to -15ºC.

“Follow Me (Feeling)” Function
The wireless remote control incorporates a temperature sensor. The unit will automatically select the operating mode in order to achieve greater comfort and temperature control.

Cooling in Low Temperatures
Cooling operation down to -15ºC outdoors.

Multiple Outdoor Fan Speeds
Precise adjustment of the fan speed thanks to the DC motor.
TECHNICAL SPECIFICATIONS
| Model | MUPR-09-H5A | MUPR-12-H5A | MUPR-18-H5A | MUPR-24-H5A* | |||
|---|---|---|---|---|---|---|---|
| Code | CL20025 | CL20026 | CL20027 | CL20028 | |||
| Refrigeration | Nominal capacity (min ~ max) | kW | 2,5 (1,0 – 2,8) | 3,5 (1,1 – 3,7) | 5,1 (1,3 – 5,4) | 7,1 (2,0 – 7,6) | |
| Nominal consumption (min ~ max) | kW | 0,78 (0,085 – 1,0) | 1,093 (0,086 – 1,6) | 1,58 (0,2 – 2,0) | 2,2 (0,3 – 2,9) | ||
| Pdesignc (design load) | kW | 2,5 | 3,5 | 5,1 | 6,8 | ||
| SEER | W/W | 6,30 | 6,43 | 6,18 | 6,33 | ||
| Energy Labeling | A++ | A++ | A++ | A++ | |||
| Heating | Nominal capacity (min ~ max) | kW | 2,6 (0,69 – 2,9) | 3,5 (1,1 – 3,8) | 5,3 (1,4 – 6,1) | 7,3 (2,5 – 8,0) | |
| Nominal consumption (min ~ max) | kW | 0,72 (0,11 – 1,4) | 0,97 (0,188 – 1,6) | 1,47 (0,35 – 2,2) | 2,02 (0,35 – 3,0) | ||
| Intermediate climate zone | Pdesignh (design load) | kW | 2,4 | 3,5 | 4,7 | 5,6 | |
| SCOP | W/W | 4,10 | 4,07 | 4,08 | 4,10 | ||
| Energy label | A+ | A+ | A+ | A+ | |||
| Tbiv (Bivalent temperature) | ºC | 2 | 2 | 2 | 2 | ||
| Tol (Operating limit temperature) | ºC | -10 | -10 | -10 | -10 | ||
| Electrical Power | V-Hz-F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | ||
| Maximum consumption | kW | 1,5 | 1,9 | 2,8 | 3,2 | ||
| Maximum intensity | A | 8 | 9,5 | 11 | 16 | ||
| Indoor Unit | Air flow (Turbo / High / Medium / Low) | m3/h | 550 / 500 / 450 / 405 | 550 / 500 / 450 / 405 | 900 / 818 / 740 / 666 | 1250 / 1090 / 990 / 890 | |
| Sound pressure (Turbo / High / Medium / Low) | dB(A) | 42 / 37 / 33 / 27 | 42 / 37 / 33 / 27 | 48 / 43 / 38 / 32 | 50 / 45 / 40 / 34 | ||
| Sound power (High) | dB(A) | 51 | 53 | 59 | 64 | ||
| Dimensions (W x H x D) | mm | 750 x 285 x 200 | 750 x 285 x 200 | 900 x 311 x 225 | 1082 x 330 x 233 | ||
| Weight | Kg | 8 | 8,5 | 12 | 16 | ||
| Outdoor Unit | Air flow (max) | m3/h | 2000 | 2000 | 2150 | 300 | |
| Sound pressure (High) | dB(A) | 52 | 52 | 54 | 55 | ||
| Sound power (High) | dB(A) | 57 | 60 | 62 | 66 | ||
| Dimensions (W x H x D) | mm | 730 x 545 x 285 | 730 x 545 x 285 | 800 x 545 x 315 | 900 x 700 x 350 | ||
| Weight | Kg | 27 | 27 | 35 | 46 | ||
| Refrigerant | Type | R410A | R410A | R410A | R410A | ||
| Load | Kg | 0,78 | 0,78 | 1,4 | 1,6 | ||
| Precharge up to | m | 5 | 5 | 5 | 5 | ||
| Additional charge (from 5m) | g/m | 20 | 25 | 30 | 40 | ||
| Refrigerant pipes | Liquid | mm(inch) | 6.35 (1/4″) | 6.35 (1/4″) | 6.35 (1/4″) | 9.52 (3/8″) | |
| Gas | mm(inch) | 9.52 (3/8″) | 9.52 (3/8″) | 12.7 (1/2″) | 15.9 (5/8″) | ||
| Maximum length | m | 20 | 20 | 25 | 25 | ||
| Maximum height difference | m | 10 | 10 | 15 | 15 | ||
| Electrical Wiring | Power supply (indoor unit) | mm2 | 2 x 2.5 + T | 2 x 2.5 + T | 2 x 2.5 + T | 2 x 4 + T | |
| Interconnection | mm2 | 3 x 2,5 + T | 3 x 2,5 + T | 3 x 2,5 + T | 3 x 4 + T | ||
| Wireless Remote Control | H Series | H Series | H Series | H Series | |||
| Operating temperature | Indoor (Cooling / Heating) | ºC | 18 ~ 32 / 0 ~ 30 | 18 ~ 32 / 0 ~ 30 | 18 ~ 32 / 0 ~ 30 | 18 ~ 32 / 0 ~ 30 | |
| Outdoor (Cooling / Heating) | ºC | -10 ~ 47 / -10 ~ 30 | -10 ~ 47 / -10 ~ 30 | -10 ~ 47 / -10 ~ 30 | -10 ~ 47 / -10 ~ 30 | ||
Warning:
1. Data and Specifications are Subject to Change without Notice.
2. The Sound Level Values Correspond to the Values Obtained in the Anechoic Chamber.
PRE-INSTALLATION REQUIREMENTS
| MODEL | PIPING | ELECTRICAL CONNECTIONS | ||||||
|---|---|---|---|---|---|---|---|---|
| Gas | Liquid | Maximum length (B) | Maximum height difference (A) | Precharge up to | Additional charge | Power supply (D) | Interconnection (C) | |
| MUPR-09-H5A | 3/8″ | 1/4″ | 20 m | 10 m | 5 m | 20 gr/m | 2 x 2.5 + T | 3 x 2.5 + T |
| MUPR-12-H5A | 3/8″ | 1/4″ | 20 m | 10 m | 5 m | 25 gr/m | 2 x 2.5 + T | 3 x 2.5 + T |
| MUPR-18-H5A | 1/2″ | 1/4″ | 25 m | 15 m | 5 m | 30 gr/m | 2 x 2.5 + T | 3 x 2.5 + T |
| MUPR-24-H5A | 5/8″ | 3/8″ | 25 m | 15 m | 5 m | 40 gr/m | 2 x 4 + T | 3 x 4 + T |