Maxi MVD V6X (2 pipes)
The new Super DC Inverter modular system Maxi MVD V6X (2 pipes) consisting of 12 basic modules that can be combined with each other, allows a maximum power of up to 270 kW, which is the highest on the market, and supports a maximum pipe length of up to 1000 m.
VERSATILITY – up to 13 Modules
The Super DC Inverter Maxi MVD V6X modular system consists of 13 basic modules, of which up to 3 can be combined as the customer wishes, forming a total system capacity ranging from 8 HP to 96 HP (270kW) in 2 HP increments.
HIGH EFFICIENCY – Scroll DC Inverter EVI Compressor (Enhanced Vapor Injection)
The EVI compressor allows the unit to operate in heating mode down to -25°C thanks to the 2 compression stages and the wide frequency range of between 15 – 140Hz.
HIGH EFFICIENCY – Plate Heat Exchanger
The plate heat exchanger increases the sub-cooling of the refrigerant, resulting in a 10% improvement in energy efficiency and a reduction in refrigerant flow noise.
HIGH EFFICIENCY – Floating Evaporation/Condensation Temperature
The evaporation temperature (in cooling) and the condensation temperature (in heating) are automatically adjusted according to the indoor and outdoor temperature to balance comfort and energy efficiency.
HIGH EFFICIENCY – High-efficiency Heat Exchanger
The 24 to 32 HP modules incorporate a 3-row G-type battery, with an exchange surface 1.5 times larger than that of the 22 HP module.
The 24 to 32 HP modules also have super large fans with a diameter of up to 750 mm.
COMFORT – Wide Operating Range
The V6X series can operate stably in heating between -25°C and 24°C, with 100% performance down to -5°C and in cooling between -5°C and 48°C.
COMFORT – Multiple Silent Modes
Silent mode includes several programming options that can be used to reduce noise levels at times when low-noise operation is required.
In total there are: 4 night silent modes, 3 silent modes and 4 super silent modes.
COMFORT – Mode Priority
The 5 possible configurations for establishing a priority in the operating mode, provide more freedom and convenience to meet customer needs.
In addition, the system can be locked to operate only in cooling or heating via a potential-free contact (CN91 port).
HIGH RELIABILITY – Rotation Function
This function equalizes the operating time of the outdoor units in a multiple system, significantly extending the service life of the compressors.
HIGH RELIABILITY – Double “Backup” Function
“Backup” of the compressors, the equipment can be left running with a single compressor for 4 days (only on equipment with 2 compressors).
In a multiple installation “Backup” of the modules.
HIGH RELIABILITY – Fewer Components
Integration of different components within the same electronic board, and communication between R485 bus-type boards, thus minimizing the risk of failure.
HIGH RELIABILITY – Liquid Cooling
The electrical panel is cooled by liquid cooling by passing the liquid pipe through the heat sink. Compared to the air cooling method, the PCB temperature is 10 ℃ lower.
HIGH RELIABILITY – Detection of Gas Shortage/Excess
The V6X series can detect a shortage or excess of refrigerant gas in the system.
EASIER INSTALLATION – Energy Management System
For projects with temporary power supply restrictions, the V6X series can be configured to limit its capacity between 40 ~ 100%.
EASIER INSTALLATION – Automatic Refrigerant Gas Charging
The V6X series allows the refrigerant gas to be charged to the system automatically without having to perform the additional charge calculation.
EASIER INSTALLATION – High Static Pressure
The available static pressure of the fan can be increased by simply activating a micro-switch on the control board of the outdoor unit.
EASIER INSTALLATION – Triple Configuration Possibilities
The configuration and consultation of parameters of the outdoor unit can be done in 3 ways.
EASIER INSTALLATION – up to 1000 M of Piping
The Maxi MVD V6X system allows up to 1000m of total piping.
EASIER INSTALLATION – No Oil Balance Pipe
Thanks to the new oil management technology, in modular systems, it is not required to install the oil balance pipe.
EASIER INSTALLATION – Automatic Addressing
By default, the first time the power supply to the entire system is activated, the outdoor unit automatically assigns the address to each indoor unit. Subsequently, the address of each indoor unit can be consulted and modified from its local control.
EASIER MAINTENANCE – Maintenance Mode
When maintenance mode is activated, the outdoor unit does not verify the number of indoor units connected, so the system can continue to operate without some of the indoor units.
EASIER MAINTENANCE – Settings Menu
The main board incorporates the new parameter setting menu that allows us to adjust most of the equipment functions.