{"id":43678,"date":"2015-05-06T00:00:00","date_gmt":"2015-05-05T22:00:00","guid":{"rendered":"http:\/\/212.227.145.209\/gama\/sin-categoria\/mupr-h5-series\/"},"modified":"2025-08-25T13:41:02","modified_gmt":"2025-08-25T11:41:02","slug":"mupr-h5-series","status":"publish","type":"gama","link":"https:\/\/www.mundoclima.com\/en\/gama\/domestic\/mupr-h5-series\/","title":{"rendered":"MUPR-H5 Series"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Wall Split <strong>MUPR-H5 Series<\/strong><\/h2>\n\n<h3 class=\"wp-block-heading\">Hidden LED Display<\/h3>\n\n<p>The indicator light is hidden under the front panel, so the temperature and error codes are displayed in a more elegant way.<\/p>\n\n<h3 class=\"wp-block-heading\">Turbo Operation<\/h3>\n\n<p>This function maximizes the heating or cooling effect. Thus, the environment cools down or heats up quickly, and the desired temperature is achieved in a short time. <\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-rearme-automatico.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Automatic Restart<\/h3>\n\n<p>If there is a power outage and the machine turns off, when the power returns, it automatically turns on with the last selected settings.<\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-16-emergencia.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Emergency Operation<\/h3>\n\n<p>If there is an error in the temperature sensor, the air conditioning unit will display an error code and turn off immediately.<\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-19-anti-frio-mupr.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Smart Anti-Cold Function<\/h3>\n\n<p>When activating the heating mode, the fan speed automatically increases from the lowest level to the preset level, depending on the heating of the evaporator. This avoids the emission of initial cold air, which is uncomfortable for the user. <\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-3-turbo.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Turbo Operation<\/h3>\n\n<p>This function maximizes the heating or cooling effect. Thus, the environment cools down or heats up quickly, and the desired temperature is achieved in the shortest possible time. <\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-deteccion-fugas.png\" alt=\"Refrigerant leak detection\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Refrigerant Leak Detection<\/h3>\n\n<p>Thanks to this new technology, the indoor unit emits an alarm if a refrigerant leak is detected in the outdoor unit.<\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/Auto-limpieza.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Self-cleaning<\/h3>\n\n<p>This function cleans the interior battery, keeping the equipment dry and preventing bacteria from forming.<\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/Arranque-a-bajo-voltaje2.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Low Voltage Start<\/h3>\n\n<p>The equipment can start and function normally up to a supply voltage of 165V.<\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/02\/icona-standby.png\" alt=\"Stanby function (only 1w)\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Standby Function (Only 1w)<\/h3>\n\n<p>The intelligent ON\/OFF technology allows energy saving in Standby mode. This allows reducing the<br\/>energy consumption from 4-5W to 1W, resulting in an energy saving of 80%. <\/p>\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/Funci%C3%B3n-Feeling.png\" alt=\"\"\/><\/figure>\n\n<h3 class=\"wp-block-heading\">Feeling Function<\/h3>\n\n<p>The wireless remote control incorporates a temperature sensor. The unit will automatically select the operating mode in order to achieve greater control and comfort in the temperature. <\/p>\n\n<h2 class=\"wp-block-heading\">TECHNICAL SPECIFICATIONS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th colspan=\"3\">Model<\/th><th>MUPR-09-H5<\/th><th>MUPR-12-H5<\/th><th>MUPR-18-H5<\/th><\/tr><\/thead><tbody><tr><td colspan=\"3\">Code<\/td><td>CL 20 736<\/td><td>CL 20 737<\/td><td>CL 20 738<\/td><\/tr><tr><td rowspan=\"3\">Refrigeration<\/td><td rowspan=\"2\">Capacity<\/td><td>kW<\/td><td>2,5<\/td><td>3,5<\/td><td>5,2<\/td><\/tr><tr><td>Kcal\/h<\/td><td>2.150<\/td><td>3.010<\/td><td>4.472<\/td><\/tr><tr><td>Nominal consumption (max)<\/td><td>W<\/td><td>778 (1.500)<\/td><td>1.080 (1.800)<\/td><td>1.700 (2.250)<\/td><\/tr><tr><td rowspan=\"3\">Heating<\/td><td rowspan=\"2\">Capacity<\/td><td>kW<\/td><td>2,6<\/td><td>3,6<\/td><td>5,3<\/td><\/tr><tr><td>Kcal\/h<\/td><td>2.236<\/td><td>3.096<\/td><td>4.558<\/td><\/tr><tr><td>Nominal consumption (max)<\/td><td>W<\/td><td>715 (1.500)<\/td><td>984 (1.800)<\/td><td>2.100 (2.250)<\/td><\/tr><tr><td colspan=\"2\">SEER<\/td><td>W\/W<\/td><td>5,6<\/td><td>5,6<\/td><td>5,6<\/td><\/tr><tr><td colspan=\"2\">Energy Efficiency Class Cooling<\/td><td><\/td><td>A+<\/td><td>A+<\/td><td>A+<\/td><\/tr><tr><td colspan=\"2\">SCOP<\/td><td>W\/W<\/td><td>3,8<\/td><td>3,8<\/td><td>3,8<\/td><\/tr><tr><td colspan=\"2\">Energy Efficiency Class Heating<\/td><td><\/td><td>A<\/td><td>A<\/td><td>A<\/td><\/tr><tr><td colspan=\"2\">Minimum operating temperature<\/td><td>\u00baC<\/td><td>-10<\/td><td>-10<\/td><td>-10<\/td><\/tr><tr><td colspan=\"2\">Indoor air flow (High)<\/td><td>m\u00b3\/h<\/td><td>500<\/td><td>560<\/td><td>920<\/td><\/tr><tr><td colspan=\"2\">Indoor sound pressure (High)<\/td><td>dB (A)<\/td><td>42<\/td><td>42<\/td><td>47<\/td><\/tr><tr><td colspan=\"2\">Outdoor air flow (High)<\/td><td>m\u00b3\/h<\/td><td>1.690<\/td><td>1.950<\/td><td>2.500<\/td><\/tr><tr><td colspan=\"2\">Outdoor sound pressure (High)<\/td><td>dB (A)<\/td><td>54<\/td><td>55<\/td><td>57<\/td><\/tr><tr><td rowspan=\"2\">Net dimensions (mm)<\/td><td>Interior (W x D x H)<\/td><td>mm<\/td><td>802 x 190 x 265<\/td><td>802 x 190 x 265<\/td><td>940 x 220 x 300<\/td><\/tr><tr><td>Exterior (W x D x H)<\/td><td>mm<\/td><td>720 x 260 x 540<\/td><td>760 x 260 x 540<\/td><td>800 x 300 x 690<\/td><\/tr><tr><td rowspan=\"2\">Net weight<\/td><td>Indoor<\/td><td>kg<\/td><td>7<\/td><td>7<\/td><td>12<\/td><\/tr><tr><td>Outdoor<\/td><td>kg<\/td><td>26<\/td><td>27<\/td><td>46<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant pipes<\/td><td>Liquid<\/td><td>inches<\/td><td>1\/4&#8243;<\/td><td>1\/4&#8243;<\/td><td>1\/4&#8243;<\/td><\/tr><tr><td>Gas<\/td><td>inches<\/td><td>3\/8&#8243;<\/td><td>1\/2&#8243;<\/td><td>5\/8&#8243;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h6 class=\"wp-block-heading\">Warning:<br\/>1. Data and Specifications are Subject to Change without Notice.<br\/>2. The Sound Level Values Correspond to the Values Obtained in the Anechoic Chamber.<\/h6>\n\n<h2 class=\"wp-block-heading\">PRE-INSTALLATION REQUIREMENTS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>MODEL<\/th><th colspan=\"6\">PIPING<\/th><th colspan=\"2\">ELECTRICAL CONNECTIONS<\/th><\/tr><\/thead><tbody><tr><td><\/td><td>Gas<\/td><td>Liquid<\/td><td>Maximum length (B)<\/td><td>Maximum height difference (A)<\/td><td>Precharge up to<\/td><td>Additional charge<\/td><td>Power supply (D)<\/td><td>Interconnection (C)<\/td><\/tr><tr><td>MUPR-09-H5<\/td><td>3\/8&#8243;<\/td><td>1\/4&#8243;<\/td><td>15 m<\/td><td>5 m<\/td><td>5 m<\/td><td>20 gr\/m<\/td><td>2 x 2.5 + T<\/td><td>3 x 2.5 + T<\/td><\/tr><tr><td>MUPR-12-H5<\/td><td>1\/2&#8243;<\/td><td>1\/4&#8243;<\/td><td>15 m<\/td><td>5 m<\/td><td>5 m<\/td><td>20 gr\/m<\/td><td>2 x 2.5 + T<\/td><td>3 x 2.5 + T<\/td><\/tr><tr><td>MUPR-18-H5<\/td><td>5\/8&#8243;<\/td><td>1\/4&#8243;<\/td><td>15 m<\/td><td>5 m<\/td><td>5 m<\/td><td>30 gr\/m<\/td><td>2 x 4 + T<\/td><td>3 x 4 + T<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"468\" height=\"242\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen.png\" alt=\"\" class=\"wp-image-7458\" srcset=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen.png 468w, https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen-300x155.png 300w\" sizes=\"(max-width: 468px) 100vw, 468px\" \/><\/figure>\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"491\" height=\"242\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen-1.png\" alt=\"\" class=\"wp-image-7459\" srcset=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen-1.png 491w, https:\/\/www.mundoclima.com\/wp-content\/uploads\/2015\/05\/imagen-1-300x148.png 300w\" sizes=\"(max-width: 491px) 100vw, 491px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Wall Split MUPR-H5 Series Hidden LED Display The indicator light is hidden under the front panel, so the temperature and error codes are displayed in a more elegant way. Turbo Operation This function maximizes the heating or cooling effect. Thus, the environment cools down or heats up quickly, and the desired temperature is achieved in [&hellip;]<\/p>\n","protected":false},"featured_media":40695,"parent":0,"menu_order":0,"template":"","categoria-productos":[122,239],"etiqueta_producto":[60],"class_list":["post-43678","gama","type-gama","status-publish","has-post-thumbnail","hentry","categoria-productos-domestic","categoria-productos-wall-split-other-seasons","etiqueta_producto-otras-temporadas"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama"}],"about":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/types\/gama"}],"version-history":[{"count":1,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43678\/revisions"}],"predecessor-version":[{"id":43680,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43678\/revisions\/43680"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media\/40695"}],"wp:attachment":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media?parent=43678"}],"wp:term":[{"taxonomy":"categoria-productos","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/categoria-productos?post=43678"},{"taxonomy":"etiqueta_producto","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/etiqueta_producto?post=43678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}