{"id":43669,"date":"2016-02-01T00:00:00","date_gmt":"2016-01-31T23:00:00","guid":{"rendered":"http:\/\/212.227.145.209\/gama\/sin-categoria\/muchr-h6-series\/"},"modified":"2025-08-25T13:40:48","modified_gmt":"2025-08-25T11:40:48","slug":"muchr-h6-series","status":"publish","type":"gama","link":"https:\/\/www.mundoclima.com\/en\/gama\/commercial\/muchr-h6-series\/","title":{"rendered":"MUCHR-H6 Series"},"content":{"rendered":"\n<p><strong>Models 20 to 26<\/strong><\/p>\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"685\" height=\"397\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2016\/02\/40-a-45kw-1.png\" alt=\"\" class=\"wp-image-7278\" srcset=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2016\/02\/40-a-45kw-1.png 685w, https:\/\/www.mundoclima.com\/wp-content\/uploads\/2016\/02\/40-a-45kw-1-300x174.png 300w\" sizes=\"(max-width: 685px) 100vw, 685px\" \/><\/figure>\n\n<p><strong>Models 40 and 45<\/strong><\/p>\n\n<h2 class=\"wp-block-heading\">TECHNICAL SPECIFICATIONS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th colspan=\"3\">Model<\/th><th>MUCHR-20-H6<\/th><th>MUCHR-22-H6<\/th><th>MUCHR-26-H6<\/th><th>MUCHR-40-H6<\/th><th>MUCHR-45-H6<\/th><\/tr><\/thead><tbody><tr><td colspan=\"3\">Code<\/td><td>CL23904<\/td><td>CL23905<\/td><td>CL23906<\/td><td>CL23912<\/td><td>CL23913<\/td><\/tr><tr><td rowspan=\"4\">Cooling (1)<\/td><td rowspan=\"2\">Capacity<\/td><td>kW<\/td><td>19,66<\/td><td>22,53<\/td><td>25,95<\/td><td>38,96<\/td><td>43,95<\/td><\/tr><tr><td>kcal\/h<\/td><td>16.910<\/td><td>19.378<\/td><td>22.320<\/td><td>33.509<\/td><td>37.801<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>6,90<\/td><td>7,60<\/td><td>8,40<\/td><td>14,60<\/td><td>16,30<\/td><\/tr><tr><td>EER<\/td><td>kW\/kW<\/td><td>2,85<\/td><td>2,96<\/td><td>3,09<\/td><td>2,67<\/td><td>2,70<\/td><\/tr><tr><td rowspan=\"4\">Heating (2)<\/td><td rowspan=\"2\">Capacity<\/td><td>kW<\/td><td>19,86<\/td><td>22,18<\/td><td>25,78<\/td><td>41,35<\/td><td>45,38<\/td><\/tr><tr><td>kcal\/h<\/td><td>17.082<\/td><td>19.077<\/td><td>22.174<\/td><td>35.565<\/td><td>39.031<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>6,90<\/td><td>6,70<\/td><td>8,40<\/td><td>13,80<\/td><td>15,40<\/td><\/tr><tr><td>COP<\/td><td>kW\/kW<\/td><td>2,88<\/td><td>3,31<\/td><td>3,07<\/td><td>3,00<\/td><td>2,95<\/td><\/tr><tr><td rowspan=\"11\">Indoor Unit<\/td><td>MVD- Model<\/td><td><\/td><td>200T1\/DHN1-B<\/td><td>250T1\/DHN1-B<\/td><td>280T1\/DHN1-B<\/td><td>D400T1\/N1-F<\/td><td>D450T1\/N1-F<\/td><\/tr><tr><td>Code<\/td><td><\/td><td>CL23381<\/td><td>CL23382<\/td><td>CL23383<\/td><td>CL23187<\/td><td>CL23188<\/td><\/tr><tr><td>Electrical Power<\/td><td>F, V, Hz<\/td><td colspan=\"5\">1N-, 220-240V, 50Hz<\/td><\/tr><tr><td>Nominal Intensity<\/td><td>A<\/td><td>6<\/td><td>6<\/td><td>6<\/td><td>12,5<\/td><td>12,5<\/td><\/tr><tr><td>Flow Rate (High \/ Medium \/ Low)<\/td><td>m3\/h<\/td><td>4820 \/ 4660 \/ 4620<\/td><td>4820 \/ 4660 \/ 4620<\/td><td>4820 \/ 4660 \/ 4620<\/td><td>7474 \/ 6072 \/ 4995<\/td><td>7474 \/ 6072 \/ 4995<\/td><\/tr><tr><td>Static Pressure Disp.<\/td><td>Pa<\/td><td>62 (40  200)<\/td><td>62 (40  200)<\/td><td>62 (40  200)<\/td><td>200 (50  280)<\/td><td>200 (50  280)<\/td><\/tr><tr><td>Sound Pressure (High \/ Medium \/ Low) (3)<\/td><td>dB(A)<\/td><td>57 \/ 53 \/ 50<\/td><td>57 \/ 53 \/ 50<\/td><td>57 \/ 53 \/ 50<\/td><td>61 \/ 59 \/ 56<\/td><td>61 \/ 59 \/ 56<\/td><\/tr><tr><td>Dimensions (W x H x D)<\/td><td>mm<\/td><td>1450 x 505 x 925<\/td><td>1450 x 505 x 925<\/td><td>1450 x 505 x 925<\/td><td>1970 x 668 x 902.5<\/td><td>1970 x 668 x 902.5<\/td><\/tr><tr><td>Weight<\/td><td>kg<\/td><td>108<\/td><td>108<\/td><td>108<\/td><td>232<\/td><td>232<\/td><\/tr><tr><td>Drain Connection<\/td><td>mm<\/td><td>32<\/td><td>32<\/td><td>32<\/td><td>32<\/td><td>32<\/td><\/tr><tr><td>Power Cable (5)<\/td><td>mm2<\/td><td>2 x 2.5 + T<\/td><td>2 x 2.5 + T<\/td><td>2 x 2.5 + T<\/td><td>2 x 4 + T<\/td><td>2 x 4 + T<\/td><\/tr><tr><td rowspan=\"10\">Outdoor Unit<\/td><td>MVD- Model<\/td><td><\/td><td>V200W\/DRN1<\/td><td>V224W\/DRN1<\/td><td>V260W\/DRN1<\/td><td>V400W\/DRN1<\/td><td>V450W\/DRN1<\/td><\/tr><tr><td>Code<\/td><td><\/td><td>CL23269<\/td><td>CL23270<\/td><td>CL23271<\/td><td>CL23272<\/td><td>CL23273<\/td><\/tr><tr><td>Electrical Power<\/td><td>F, V, Hz<\/td><td colspan=\"5\">3N-, 400V, 50Hz<\/td><\/tr><tr><td>Nominal Intensity<\/td><td>A<\/td><td>14,50<\/td><td>16,20<\/td><td>18,70<\/td><td>33,00<\/td><td>44,00<\/td><\/tr><tr><td>Flow<\/td><td>m3\/h<\/td><td>10.999<\/td><td>10.494<\/td><td>10.494<\/td><td>16.575<\/td><td>16.575<\/td><\/tr><tr><td>Static Pressure Disp.<\/td><td>Pa<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>Sound Pressure (4)<\/td><td>dB(A)<\/td><td>59<\/td><td>59<\/td><td>60<\/td><td>62<\/td><td>62<\/td><\/tr><tr><td>Dimensions (W x H x D)<\/td><td>mm<\/td><td>1120 x 1558 x 414<\/td><td>1120 x 1558 x 414<\/td><td>1120 x 1558 x 414<\/td><td>1360 x 1650 x 540<\/td><td>1460 x 1650 x 540<\/td><\/tr><tr><td>Weight<\/td><td>Kg<\/td><td>137<\/td><td>147<\/td><td>147<\/td><td>240<\/td><td>275<\/td><\/tr><tr><td>Power Cable (5)<\/td><td>mm2<\/td><td>4 x 6 + T<\/td><td>4 x 6 + T<\/td><td>4 x 10 + T<\/td><td>4 x 25 + T<\/td><td>4 x 35 + T<\/td><\/tr><tr><td rowspan=\"3\">Refrigerant<\/td><td>Type<\/td><td><\/td><td colspan=\"5\">R410A<\/td><\/tr><tr><td>Pre-charged amount<\/td><td>kg<\/td><td>4,8<\/td><td>6,2<\/td><td>6,2<\/td><td>9,0<\/td><td>12,0<\/td><\/tr><tr><td>Additional charge (from 0 m)<\/td><td>kg\/m<\/td><td>0,057<\/td><td>0,057<\/td><td>0,057<\/td><td>0,110<\/td><td>0,110<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant Connections<\/td><td>Liquid Line<\/td><td>mm (in.)<\/td><td>9.52 (3\/8&#8243;)<\/td><td>9.52 (3\/8&#8243;)<\/td><td>9.52 (3\/8&#8243;)<\/td><td>12.7 (1\/2&#8243;)<\/td><td>12.7 (1\/2&#8243;)<\/td><\/tr><tr><td>Gas Line<\/td><td>mm (in.)<\/td><td>19.1 (3\/4&#8243;)<\/td><td>22.2 (7\/8&#8243;)<\/td><td>22.2 (7\/8&#8243;)<\/td><td>28.6 (1 1\/8&#8243;)<\/td><td>28.6 (1 1\/8&#8243;)<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant Distances (6)<\/td><td>Max. Vertical <\/td><td>m<\/td><td>25<\/td><td>25<\/td><td>25<\/td><td>25<\/td><td>25<\/td><\/tr><tr><td>Total<\/td><td>m<\/td><td>60<\/td><td>60<\/td><td>60<\/td><td>100<\/td><td>100<\/td><\/tr><tr><td colspan=\"2\">Communication Cable<\/td><td>mm2<\/td><td colspan=\"5\">3 x 0.75 (Shielded)<\/td><\/tr><tr><td rowspan=\"2\">Remote control<\/td><td>Model<\/td><td><\/td><td colspan=\"5\">KJR-29B<\/td><\/tr><tr><td>Type<\/td><td><\/td><td colspan=\"5\">Wiring<\/td><\/tr><tr><td rowspan=\"2\">Operating Temp. Range <\/td><td>Refrigeration<\/td><td>\u00baC<\/td><td>-15 to 43<\/td><td>-15 to 43<\/td><td>-15 to 43<\/td><td>-5 to 43<\/td><td>-5 to 43<\/td><\/tr><tr><td>Heating<\/td><td>\u00baC<\/td><td>-15 to 24<\/td><td>-15 to 24<\/td><td>-15 to 24<\/td><td>-15 to 24<\/td><td>-15 to 24<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Notes:<\/strong><\/p>\n\n<p>(1) Nominal cooling conditions: indoor 27\u00baC DB, 19\u00baC WB and outdoor 35\u00baC DB, for an equivalent pipe length of 8 m and height difference of 0 m.<\/p>\n\n<p>(2) Nominal heating conditions: indoor 20\u00baC DB, 15\u00baC WB and outdoor 7\u00baC DB, for an equivalent pipe length of 8 m and height difference of 0 m.<\/p>\n\n<p>(3) Sound pressure measured in an anechoic chamber at a distance of 1m from the front and 1.4m in height.<\/p>\n\n<p>(4) Sound pressure measured in an anechoic chamber at a distance of 1m from the front and 1.2m in height (1.3m for models 20 to 26).<\/p>\n\n<p>(5) Recommended power wiring for L  20m, for longer distances it must be calculated.<\/p>\n\n<p>(6) Refrigerant distances when the outdoor unit is installed lower than the indoor units. Otherwise, instead of 30m it is 20m. <\/p>\n\n<p><em>The design and specifications are subject to change without notice for product improvement.<\/em><\/p>\n\n<p><strong>Attention:<\/strong><\/p>\n\n<p>\u2013 Before start-up, the entire micro-switch S6 must be set to the OFF position on the outdoor unit.<\/p>\n\n<p>\u2013 Models 40 and 45 do not include an air filter.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Models 20 to 26 Models 40 and 45 TECHNICAL SPECIFICATIONS Model MUCHR-20-H6 MUCHR-22-H6 MUCHR-26-H6 MUCHR-40-H6 MUCHR-45-H6 Code CL23904 CL23905 CL23906 CL23912 CL23913 Cooling (1) Capacity kW 19,66 22,53 25,95 38,96 43,95 kcal\/h 16.910 19.378 22.320 33.509 37.801 Consumption kW 6,90 7,60 8,40 14,60 16,30 EER kW\/kW 2,85 2,96 3,09 2,67 2,70 Heating (2) Capacity kW [&hellip;]<\/p>\n","protected":false},"featured_media":40009,"parent":0,"menu_order":0,"template":"","categoria-productos":[127,147],"etiqueta_producto":[60],"class_list":["post-43669","gama","type-gama","status-publish","has-post-thumbnail","hentry","categoria-productos-commercial","categoria-productos-duct","etiqueta_producto-otras-temporadas"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43669","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama"}],"about":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/types\/gama"}],"version-history":[{"count":1,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43669\/revisions"}],"predecessor-version":[{"id":43670,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43669\/revisions\/43670"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media\/40009"}],"wp:attachment":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media?parent=43669"}],"wp:term":[{"taxonomy":"categoria-productos","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/categoria-productos?post=43669"},{"taxonomy":"etiqueta_producto","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/etiqueta_producto?post=43669"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}