{"id":43665,"date":"2016-02-08T00:00:00","date_gmt":"2016-02-07T23:00:00","guid":{"rendered":"http:\/\/212.227.145.209\/gama\/sin-categoria\/muenr-h6-series\/"},"modified":"2025-08-25T13:40:26","modified_gmt":"2025-08-25T11:40:26","slug":"muenr-h6-series","status":"publish","type":"gama","link":"https:\/\/www.mundoclima.com\/en\/gama\/industrial-en\/chillers-and-fan-coils\/muenr-h6-series\/","title":{"rendered":"MUENR-H6 Series"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">Inverter Chillers <strong>MUENR-H6 Series<\/strong> <\/h1>\n\n<h3 class=\"wp-block-heading\">Compressor and DC Inverter Fan Motor<\/h3>\n\n<p>All equipment in the range incorporates a DC Inverter compressor and fan motor, thus improving system performance at medium frequencies and ensuring more sensitive and effective control.<\/p>\n\n<h3 class=\"wp-block-heading\"><strong>High-efficiency Recirculating Pump<\/strong><\/h3>\n\n<p>Compliant with the ERP ecodesign directive, new high-efficiency pump, allows to reduce consumption.<\/p>\n\n<h3 class=\"wp-block-heading\">Hydraulic Module<\/h3>\n\n<p>Fully integrated hydraulic module equipped with hydraulic components such as expansion vessel, plate heat exchanger and circulating pump.<\/p>\n\n<h3 class=\"wp-block-heading\">Plate Heat Exchanger<\/h3>\n\n<p>The plate heat exchanger is made of AISI 316 stainless steel to ensure high thermal exchange efficiency. It also has an electric heater and a differential pressure switch. <\/p>\n\n<h3 class=\"wp-block-heading\">Remote Stop and Mode Selection Signals<\/h3>\n\n<p>Possibility of stopping the equipment and selecting the operating mode by means of a potential-free remote signal.<\/p>\n\n<h3 class=\"wp-block-heading\">Wide Range of Operating Temperatures<\/h3>\n\n<p>MUENR-H6 units can operate in extreme temperature conditions, in heating mode down to a temperature of -15\u00baC and in cooling mode up to 46\u00baC.<\/p>\n\n<h3 class=\"wp-block-heading\">Energy Saving and High Reliability<\/h3>\n\n<p>Thanks to the high-efficiency plate heat exchanger and the DC Inverter compressor and fan motor, energy consumption is reduced and the equipment&#8217;s operation is optimized.<\/p>\n\n<h3 class=\"wp-block-heading\"><strong>Wired Wall Remote Control (Optional)<\/strong><\/h3>\n\n<p>All units incorporate a control panel integrated in the unit that allows to adjust all operating parameters. However, there is the possibility of acquiring a wired wall remote control to be able to control the unit from inside the house (KJR-120F1-BMK-E (CL92340)) <\/p>\n\n<p><strong>Wired wall remote control<\/strong><\/p>\n\n<figure class=\"wp-block-image aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.mundoclima.com\/wp-content\/uploads\/2016\/02\/CL92340.png\" alt=\"CL92340\" class=\"wp-image-16872\" style=\"width:207px;height:auto\"\/><\/figure>\n\n<p>(optional CL92340)<\/p>\n\n<h2 class=\"wp-block-heading\">TECHNICAL SPECIFICATIONS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th colspan=\"4\">Model<\/th><th>MUENR-05-H6<\/th><th>MUENR-07-H6<\/th><th>MUENR-10-H6<\/th><th>MUENR-12-H6<\/th><th>MUENR-12-H6T<\/th><th>MUENR-14-H6T<\/th><th>MUENR-16-H6T<\/th><\/tr><\/thead><tbody><tr><td colspan=\"4\">Code<\/td><td>CL25620<\/td><td>CL25621<\/td><td>CL25622<\/td><td>CL25623<\/td><td>CL25626<\/td><td>CL25627<\/td><td>CL25628<\/td><\/tr><tr><td>Power supply<\/td><td><\/td><td><\/td><td>V \/ F \/ Hz<\/td><td>220 &#8211; 240 \/ 1N \/ 50<\/td><td>220 &#8211; 240 \/ 1N \/ 50<\/td><td>220 &#8211; 240 \/ 1N \/ 50<\/td><td>220 &#8211; 240 \/ 1N \/ 50<\/td><td>380 &#8211; 415 \/ 3N \/ 50<\/td><td>380 &#8211; 415 \/ 3N \/ 50<\/td><td>380 &#8211; 415 \/ 3N \/ 50<\/td><\/tr><tr><td rowspan=\"7\">Refrigeration<\/td><td rowspan=\"3\">Conditions 1 *(1)<\/td><td>Capacity (min ~ max)<\/td><td>kW<\/td><td>5.0 (1.9 ~ 5.8)<\/td><td>7.0 (2.1 ~ 7.8)<\/td><td>10.0 (2.9 ~ 10.5)<\/td><td>11.2 (3.1 ~ 12.0)<\/td><td>11.2 (3.1 ~ 12.0)<\/td><td>12.5 (3.3 ~ 14.0)<\/td><td>14.5 (3.5 ~ 15.5)<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>1,55<\/td><td>2,25<\/td><td>2,95<\/td><td>3,50<\/td><td>3,38<\/td><td>3,90<\/td><td>4,70<\/td><\/tr><tr><td>EER<\/td><td>kW \/ kW<\/td><td>3,23<\/td><td>3,11<\/td><td>3,39<\/td><td>3,20<\/td><td>3,31<\/td><td>3,20<\/td><td>3,10<\/td><\/tr><tr><td rowspan=\"4\">Conditions 2 *(2)<\/td><td>Capacity<\/td><td>kW<\/td><td>5,60<\/td><td>8,00<\/td><td>10,60<\/td><td>12,20<\/td><td>12,20<\/td><td>14,20<\/td><td>15,60<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>1,15<\/td><td>1,85<\/td><td>2,30<\/td><td>2,65<\/td><td>2,60<\/td><td>3,10<\/td><td>3,60<\/td><\/tr><tr><td>EER<\/td><td>kW \/ kW<\/td><td>4,87<\/td><td>4,32<\/td><td>4,24<\/td><td>4,60<\/td><td>4,70<\/td><td>4,58<\/td><td>4,33<\/td><\/tr><tr><td>SEER<\/td><td>kW \/ kW<\/td><td>5,83<\/td><td>6,07<\/td><td>5,71<\/td><td>6,37<\/td><td>6,18<\/td><td>6,69<\/td><td>6,78<\/td><\/tr><tr><td rowspan=\"7\">Heating<\/td><td rowspan=\"3\">Conditions 3 *(3)<\/td><td>Capacity (min ~ max)<\/td><td>kW<\/td><td>6.2 (2.1 ~ 7.0)<\/td><td>8.0 (2.3 ~ 9.0)<\/td><td>11.0 (3.1 ~ 12.0)<\/td><td>12.3 (3.3 ~ 13.2)<\/td><td>12.3 (3.3 ~ 13.2)<\/td><td>13.8 (3.5 ~ 15.4)<\/td><td>16.0 (3.7 ~ 17.0)<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>1,90<\/td><td>2,50<\/td><td>3,14<\/td><td>3,78<\/td><td>3,72<\/td><td>4,25<\/td><td>4,85<\/td><\/tr><tr><td>COP<\/td><td>kW \/ kW<\/td><td>3,26<\/td><td>3,20<\/td><td>3,50<\/td><td>3,25<\/td><td>3,31<\/td><td>3,25<\/td><td>3,30<\/td><\/tr><tr><td rowspan=\"4\">Conditions 4 *(4)<\/td><td>Capacity<\/td><td>kW<\/td><td>6,20<\/td><td>8,60<\/td><td>11,50<\/td><td>13,00<\/td><td>13,00<\/td><td>15,10<\/td><td>16,50<\/td><\/tr><tr><td>Consumption<\/td><td>kW<\/td><td>1,35<\/td><td>2,10<\/td><td>2,65<\/td><td>2,92<\/td><td>2,85<\/td><td>3,35<\/td><td>3,92<\/td><\/tr><tr><td>COP<\/td><td>kW \/ kW<\/td><td>4,60<\/td><td>4,10<\/td><td>4,34<\/td><td>4,45<\/td><td>4,56<\/td><td>4,51<\/td><td>4,21<\/td><\/tr><tr><td>SCOP<\/td><td>kW \/ kW<\/td><td>3,55<\/td><td>3,46<\/td><td>3,34<\/td><td>3,46<\/td><td>3,66<\/td><td>3,78<\/td><td>3,39<\/td><\/tr><tr><td colspan=\"2\">Energy rating at low temperature (35\u00b0C \/ \u03b7s)<\/td><td><\/td><td><\/td><td>A+ \/ 138.9%<\/td><td>A+ \/ 135.3%<\/td><td>A+ \/ 130.7%<\/td><td>A+ \/ 135.4%<\/td><td>A+ \/ 143.5%<\/td><td>A+ \/ 148.3%<\/td><td>A+ \/ 132.6%<\/td><\/tr><tr><td colspan=\"3\">Maximum intensity<\/td><td>A<\/td><td>11,40<\/td><td>13,70<\/td><td>25,00<\/td><td>26,00<\/td><td>8,90<\/td><td>9,6<\/td><td>10,1<\/td><\/tr><tr><td rowspan=\"4\">Compressor<\/td><td>Model<\/td><td><\/td><td><\/td><td>SNB172FJGMC<\/td><td>SNB172FJGMC<\/td><td>ATQ420D1UMU<\/td><td>ATQ420D1UMU<\/td><td>ATQ420D2UMU<\/td><td>ATQ420D2UMU<\/td><td>ATQ420D2UMU<\/td><\/tr><tr><td>Brand<\/td><td><\/td><td><\/td><td>Mitsubishi Electric<\/td><td>Mitsubishi Electric<\/td><td>GMCC<\/td><td>GMCC<\/td><td>GMCC<\/td><td>GMCC<\/td><td>GMCC<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant oil<\/td><td>Type<\/td><td><\/td><td>FV50S<\/td><td>FV50S<\/td><td>VG74<\/td><td>VG74<\/td><td>VG74<\/td><td>VG74<\/td><td>VG74<\/td><\/tr><tr><td>Quantity<\/td><td>ml<\/td><td>400<\/td><td>400<\/td><td>1.400<\/td><td>1.400<\/td><td>1.400<\/td><td>1.400<\/td><td>1.400<\/td><\/tr><tr><td rowspan=\"2\">Fan<\/td><td>Type \/ Motor \/ Quantity<\/td><td><\/td><td><\/td><td>AXIAL \/ DC \/ 1<\/td><td>AXIAL \/ DC \/ 1<\/td><td>AXIAL \/ DC \/ 2<\/td><td>AXIAL \/ DC \/ 2<\/td><td>AXIAL \/ DC \/ 2<\/td><td>AXIAL \/ DC \/ 2<\/td><td>AXIAL \/ DC \/ 2<\/td><\/tr><tr><td>Air flow<\/td><td><\/td><td>m3\/h<\/td><td>5.100<\/td><td>5.100<\/td><td>7.000<\/td><td>7.000<\/td><td>7.000<\/td><td>7.000<\/td><td>7.000<\/td><\/tr><tr><td rowspan=\"3\">Plate heat exchanger<\/td><td>Water flow (min ~ max)<\/td><td><\/td><td>m3\/h<\/td><td>0.86 (0.77 ~ 0.95)<\/td><td>1.24 (1.08 ~ 1.54)<\/td><td>1.72 (1.54 ~ 1.89)<\/td><td>1.92 (1.72 ~ 2.11)<\/td><td>1.92 (1.72 ~ 2.11)<\/td><td>2.15 (1.93 ~ 2.36)<\/td><td>2.49 (2.24 ~ 2.73)<\/td><\/tr><tr><td>Water volume<\/td><td><\/td><td>L<\/td><td>0,53<\/td><td>0,53<\/td><td>0,7<\/td><td>0,78<\/td><td>0,78<\/td><td>0,78<\/td><td>1,06<\/td><\/tr><tr><td>Pressure drop<\/td><td><\/td><td>kPa<\/td><td>15<\/td><td>15<\/td><td>18<\/td><td>18<\/td><td>18<\/td><td>18<\/td><td>19<\/td><\/tr><tr><td rowspan=\"3\">Water pump<\/td><td>Model<\/td><td><\/td><td><\/td><td>RS15\/6 RKC<\/td><td>RS15\/6 RKC<\/td><td>RS25\/7,5 RKC<\/td><td>RS25\/7,5 RKC<\/td><td>RS25\/7,5 RKC<\/td><td>RS25\/7,5 RKC<\/td><td>RS25\/7,5 RKC<\/td><\/tr><tr><td>Maximum flow<\/td><td><\/td><td>m3\/h<\/td><td>3,3<\/td><td>3,3<\/td><td>4<\/td><td>4<\/td><td>4<\/td><td>4<\/td><td>4<\/td><\/tr><tr><td>Elevation<\/td><td><\/td><td>m<\/td><td>5,5<\/td><td>5,5<\/td><td>7,5<\/td><td>7,5<\/td><td>7,5<\/td><td>7,5<\/td><td>7,5<\/td><\/tr><tr><td>Expansion vessel<\/td><td>Water volume<\/td><td><\/td><td>L<\/td><td>2<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>3<\/td><td>3<\/td><td>3<\/td><\/tr><tr><td colspan=\"2\">Minimum \/ maximum water inlet pressure *(5)<\/td><td><\/td><td>kPa<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><td>150 \/ 500<\/td><\/tr><tr><td colspan=\"2\">Sound pressure *(6)<\/td><td><\/td><td>dB(A)<\/td><td>58<\/td><td>58<\/td><td>59<\/td><td>59<\/td><td>62<\/td><td>62<\/td><td>62<\/td><\/tr><tr><td colspan=\"2\">Sound power *(6)<\/td><td><\/td><td>dB(A)<\/td><td>63<\/td><td>66<\/td><td>67<\/td><td>68<\/td><td>68<\/td><td>70<\/td><td>72<\/td><\/tr><tr><td colspan=\"2\">Dimensions (W x H x D)<\/td><td><\/td><td>mm<\/td><td>990 x 966 x 354<\/td><td>990 x 966 x 354<\/td><td>970 x 1327 x 400<\/td><td>970 x 1327 x 400<\/td><td>970 x 1327 x 400<\/td><td>970 x 1327 x 400<\/td><td>970 x 1327 x 400<\/td><\/tr><tr><td colspan=\"2\">Weight<\/td><td><\/td><td>kg<\/td><td>81<\/td><td>81<\/td><td>110<\/td><td>110<\/td><td>110<\/td><td>111<\/td><td>111<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant<\/td><td>Type<\/td><td><\/td><td><\/td><td>R410A<\/td><td>R410A<\/td><td>R410A<\/td><td>R410A<\/td><td>R410A<\/td><td>R410A<\/td><td>R410A<\/td><\/tr><tr><td>Quantity<\/td><td><\/td><td>kg<\/td><td>2,5<\/td><td>2,5<\/td><td>2,8<\/td><td>2,8<\/td><td>2,8<\/td><td>2,9<\/td><td>3,2<\/td><\/tr><tr><td>Electrical connections<\/td><td>Power supply<\/td><td><\/td><td>mm2<\/td><td>2 x 2.5 + T<\/td><td>2 x 2.5 + T<\/td><td>2 x 4 + T<\/td><td>2 x 4 + T<\/td><td>4 x 2.5 + T<\/td><td>4 x 2.5 + T<\/td><td>4 x 2.5 + T<\/td><\/tr><tr><td>Hydraulic connections<\/td><td>Water inlet \/ outlet<\/td><td><\/td><td>inch<\/td><td>1&#8243;<\/td><td>1&#8243;<\/td><td>1 1\/4&#8243;<\/td><td>1 1\/4&#8243;<\/td><td>1 1\/4&#8243;<\/td><td>1 1\/4&#8243;<\/td><td>1 1\/4&#8243;<\/td><\/tr><tr><td rowspan=\"2\">Operating temperature range<\/td><td>Refrigeration<\/td><td><\/td><td>\u00baC<\/td><td colspan=\"7\">&#8211; 5 ~ 46<\/td><\/tr><tr><td>Heating<\/td><td><\/td><td>\u00baC<\/td><td colspan=\"7\">&#8211; 15 ~ 27 (Below 5\u00baC antifreeze must be added)<\/td><\/tr><tr><td rowspan=\"2\">Water outlet temperature range<\/td><td>Refrigeration<\/td><td><\/td><td>\u00baC<\/td><td colspan=\"7\">In delivery 4 ~ 20 *(7)<\/td><\/tr><tr><td>Heating<\/td><td><\/td><td>\u00baC<\/td><td colspan=\"7\">In delivery 30 ~ 55 *(8)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Note:<\/strong><\/p>\n\n<p>(1) Conditions 1: Water inlet \/ outlet temperature: 12 \/ 7 \u00baC, outside temperature 35\u00baC DB.<\/p>\n\n<p>(2) Conditions 2: Water inlet \/ outlet temperature: 23 \/ 18 \u00baC, outside temperature 35\u00baC DB.<\/p>\n\n<p>(3) Conditions 3: Water inlet \/ outlet temperature: 40 \/ 45 \u00baC, outdoor temperature 7\u00baC DB \/ 6\u00baC WB \/ 85% RH.<\/p>\n\n<p>(4) Conditions 4: Water inlet \/ outlet temperature: 30 \/ 35 \u00baC, outdoor temperature 7\u00baC DB \/ 6\u00baC WB \/ 85% RH.<\/p>\n\n<p>(5) Pressures at which the pressure switches are activated.<\/p>\n\n<p>(6) Measured at 1m distance in open field.<\/p>\n\n<p>(7) The unit controls the return temperature, so the minimum adjustment temperature is 10\u00baC, the 4\u00baC are in delivery.<\/p>\n\n<p>(8) The unit controls the return temperature, so the maximum adjustment temperature is 50\u00baC, the 55\u00baC are in delivery.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Inverter Chillers MUENR-H6 Series Compressor and DC Inverter Fan Motor All equipment in the range incorporates a DC Inverter compressor and fan motor, thus improving system performance at medium frequencies and ensuring more sensitive and effective control. High-efficiency Recirculating Pump Compliant with the ERP ecodesign directive, new high-efficiency pump, allows to reduce consumption. Hydraulic Module [&hellip;]<\/p>\n","protected":false},"featured_media":40487,"parent":0,"menu_order":0,"template":"","categoria-productos":[151,111],"etiqueta_producto":[],"class_list":["post-43665","gama","type-gama","status-publish","has-post-thumbnail","hentry","categoria-productos-chillers-and-fan-coils","categoria-productos-industrial-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43665","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama"}],"about":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/types\/gama"}],"version-history":[{"count":1,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43665\/revisions"}],"predecessor-version":[{"id":43666,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43665\/revisions\/43666"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media\/40487"}],"wp:attachment":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media?parent=43665"}],"wp:term":[{"taxonomy":"categoria-productos","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/categoria-productos?post=43665"},{"taxonomy":"etiqueta_producto","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/etiqueta_producto?post=43665"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}