{"id":43473,"date":"2016-05-03T00:00:00","date_gmt":"2016-05-02T22:00:00","guid":{"rendered":"http:\/\/212.227.145.209\/gama\/sin-categoria\/100-outside-air-duct-mvd-dc\/"},"modified":"2025-08-25T13:35:45","modified_gmt":"2025-08-25T11:35:45","slug":"100-outside-air-duct-mvd-dc","status":"publish","type":"gama","link":"https:\/\/www.mundoclima.com\/en\/gama\/industrial-en\/100-outside-air-duct-mvd-dc\/","title":{"rendered":"100% outside Air Duct MVD DC"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">TECHNICAL SPECIFICATIONS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th colspan=\"4\">Model<\/th><th>MVD-125T1\/DHN1-FA<\/th><th>MVD-140T1\/DHN1-FA<\/th><th>MVD-200T1\/DHN1-FA<\/th><th>MVD-250T1\/DHN1-FA<\/th><th>MVD-280T1\/DHN1-FA<\/th><\/tr><\/thead><tbody><tr><td colspan=\"4\">Code<\/td><td>CL23390<\/td><td>CL23391<\/td><td>CL23392<\/td><td>CL23393<\/td><td>CL23394<\/td><\/tr><tr><td colspan=\"2\">Electrical Power<\/td><td><\/td><td>F, V, Hz<\/td><td colspan=\"5\">1N, 220-240, 50\/60<\/td><\/tr><tr><td rowspan=\"2\">Cooling (1)<\/td><td>Capacity<\/td><td><\/td><td>kW<\/td><td>12,5<\/td><td>14,0<\/td><td>20,0<\/td><td>25,0<\/td><td>28<\/td><\/tr><tr><td>Consumption<\/td><td><\/td><td>W<\/td><td>370<\/td><td>370<\/td><td>615<\/td><td>670<\/td><td>670<\/td><\/tr><tr><td rowspan=\"2\">Heating (2)<\/td><td>Capacity<\/td><td><\/td><td>kW<\/td><td>10,5<\/td><td>12,0<\/td><td>18,0<\/td><td>20,0<\/td><td>22<\/td><\/tr><tr><td>Consumption<\/td><td><\/td><td>W<\/td><td>370<\/td><td>370<\/td><td>615<\/td><td>670<\/td><td>670<\/td><\/tr><tr><td rowspan=\"6\">Fan<\/td><td>Type<\/td><td><\/td><td><\/td><td colspan=\"5\">DC<\/td><\/tr><tr><td>Quantity<\/td><td><\/td><td><\/td><td colspan=\"5\">1<\/td><\/tr><tr><td>Model<\/td><td><\/td><td><\/td><td>WZDK750-38GS-W<\/td><td>WZDK750-38GS-W<\/td><td>WZDK750-38GS-W<\/td><td>WZDK750-38GS-W<\/td><td>WZDK750-38GS-W<\/td><\/tr><tr><td>Flow Rate (High \/ Medium \/ Low)<\/td><td><\/td><td>m3\/h<\/td><td>2440 \/ 2000 \/ 1470<\/td><td>2440 \/ 2000 \/ 1470<\/td><td>3860 \/ 3430 \/ 2890<\/td><td>3860 \/ 3430 \/ 2890<\/td><td>3860 \/ 3430 \/ 2890<\/td><\/tr><tr><td>Sound Pressure (High \/ Medium \/ Low) (3)<\/td><td><\/td><td>dB(A)<\/td><td>52 \/ 50 \/ 48<\/td><td>52 \/ 50 \/ 48<\/td><td>52 \/ 51 \/ 19<\/td><td>53 \/ 52 \/ 50<\/td><td>53 \/ 52 \/ 50<\/td><\/tr><tr><td>Nominal Static Pressure (min-max) <\/td><td><\/td><td>Pa<\/td><td>20 (0 \u2013 196)<\/td><td>20 (0 \u2013 196)<\/td><td>62 (40 \u2013 200)<\/td><td>62 (40 \u2013 200)<\/td><td>62 (40 \u2013 200)<\/td><\/tr><tr><td rowspan=\"4\">Indoor Unit<\/td><td rowspan=\"2\">Dimensions (W x H x D)<\/td><td>Net<\/td><td>mm<\/td><td>1300 x 420 x 690<\/td><td>1300 x 420 x 690<\/td><td>1450 x 505 x 925<\/td><td>1450 x 505 x 925<\/td><td>1450 x 505 x 925<\/td><\/tr><tr><td>Gross<\/td><td>mm<\/td><td>1436 x 450 x 768<\/td><td>1436 x 450 x 768<\/td><td>1509 x 550 x 990<\/td><td>1509 x 550 x 990<\/td><td>1509 x 550 x 990<\/td><\/tr><tr><td rowspan=\"2\">Weight<\/td><td>Net<\/td><td>Kg<\/td><td>63<\/td><td>63<\/td><td>108<\/td><td>108<\/td><td>108<\/td><\/tr><tr><td>Gross<\/td><td>Kg<\/td><td>71<\/td><td>71<\/td><td>120<\/td><td>120<\/td><td>120<\/td><\/tr><tr><td>Drainage<\/td><td>Connection<\/td><td><\/td><td>mm<\/td><td>25<\/td><td>25<\/td><td>32<\/td><td>32<\/td><td>32<\/td><\/tr><tr><td>Refrigerant<\/td><td>Type<\/td><td><\/td><td><\/td><td colspan=\"5\">R410A<\/td><\/tr><tr><td rowspan=\"2\">Design Pressure<\/td><td>High<\/td><td><\/td><td>Mpa<\/td><td colspan=\"5\">4,4<\/td><\/tr><tr><td>Low<\/td><td><\/td><td>Mpa<\/td><td colspan=\"5\">2,6<\/td><\/tr><tr><td rowspan=\"2\">Refrigerant Connections<\/td><td>Liquid<\/td><td><\/td><td>mm (in.)<\/td><td>9,52 (3\/8)<\/td><td>9,52 (3\/8)<\/td><td>9.52 (3\/8) x 2<\/td><td>9.52 (3\/8) x 2<\/td><td>9.52 (3\/8) x 2<\/td><\/tr><tr><td>Gas<\/td><td><\/td><td>mm (in.)<\/td><td>15,9 (5\/8)<\/td><td>15,9 (5\/8)<\/td><td>15.9 (5\/8) x 2<\/td><td>15.9 (5\/8) x 2<\/td><td>15.9 (5\/8) x 2<\/td><\/tr><tr><td rowspan=\"2\">Electrical Connections (4)<\/td><td>Power<\/td><td><\/td><td>mm2<\/td><td colspan=\"5\">2 x 2.5 + T (L&lt;20m)<\/td><\/tr><tr><td>Signal<\/td><td><\/td><td>mm2<\/td><td colspan=\"5\">3 x 0.75 (Shielded)<\/td><\/tr><tr><td rowspan=\"2\">Remote control<\/td><td>Model<\/td><td><\/td><td><\/td><td colspan=\"5\">KJR-29B<\/td><\/tr><tr><td>Type<\/td><td><\/td><td><\/td><td colspan=\"5\">Wiring (6 m)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Notes:<\/strong><\/p>\n\n<p>(1) Nominal cooling conditions: outdoor 33\u00baC DB and 24\u00baC WB, for an equivalent pipe length of 8 m and height difference of 0 m.<\/p>\n\n<p>(2) Nominal heating conditions: outdoor 0\u00baC DB and -1\u00baC WB, for an equivalent pipe length of 8 m and height difference of 0 m.<\/p>\n\n<p>(3) Sound level measured in a semi-anechoic chamber at a frontal distance of 1m and a height of 1.4m.<\/p>\n\n<p>(4) Recommended power wiring for L &lt; 20m, for longer distances it must be calculated.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>TECHNICAL SPECIFICATIONS Model MVD-125T1\/DHN1-FA MVD-140T1\/DHN1-FA MVD-200T1\/DHN1-FA MVD-250T1\/DHN1-FA MVD-280T1\/DHN1-FA Code CL23390 CL23391 CL23392 CL23393 CL23394 Electrical Power F, V, Hz 1N, 220-240, 50\/60 Cooling (1) Capacity kW 12,5 14,0 20,0 25,0 28 Consumption W 370 370 615 670 670 Heating (2) Capacity kW 10,5 12,0 18,0 20,0 22 Consumption W 370 370 615 670 670 Fan [&hellip;]<\/p>\n","protected":false},"featured_media":8438,"parent":0,"menu_order":0,"template":"","categoria-productos":[111,232,112],"etiqueta_producto":[],"class_list":["post-43473","gama","type-gama","status-publish","has-post-thumbnail","hentry","categoria-productos-industrial-en","categoria-productos-mvd-dc-indoor-units","categoria-productos-variable-flow"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama"}],"about":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/types\/gama"}],"version-history":[{"count":1,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43473\/revisions"}],"predecessor-version":[{"id":43474,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/43473\/revisions\/43474"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media\/8438"}],"wp:attachment":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media?parent=43473"}],"wp:term":[{"taxonomy":"categoria-productos","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/categoria-productos?post=43473"},{"taxonomy":"etiqueta_producto","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/etiqueta_producto?post=43473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}