{"id":42430,"date":"2021-04-12T00:00:00","date_gmt":"2021-04-11T22:00:00","guid":{"rendered":"http:\/\/212.227.145.209\/gama\/sin-categoria\/mup-w9-series\/"},"modified":"2025-08-25T13:11:56","modified_gmt":"2025-08-25T11:11:56","slug":"mup-w9-series","status":"publish","type":"gama","link":"https:\/\/www.mundoclima.com\/en\/gama\/industrial-en\/chillers-and-fan-coils\/mup-w9-series\/","title":{"rendered":"MUP-W9 Series"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">MUP-W9 Series Wall Fan Coil Unit<\/h2>\n\n<h2 class=\"wp-block-heading\">TECHNICAL SPECIFICATIONS<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th colspan=\"4\">Model<\/th><th>MUP-09-W9<\/th><th>MUP-12-W9<\/th><th>MUP-16-W9<\/th><th>MUP-18-W9<\/th><\/tr><\/thead><tbody><tr><td colspan=\"4\">Code<\/td><td>CL04325<\/td><td>CL04326<\/td><td>CL04327<\/td><td>CL04328<\/td><\/tr><tr><td rowspan=\"4\">Cooling (1)<\/td><td colspan=\"2\">Capacity (High \/ Medium \/ Low)<\/td><td>kW<\/td><td>2,7 \/ 2,59 \/ 2,39<\/td><td>3,81 \/ 3,3 \/ 2,88<\/td><td>4,47 \/ 3,98 \/ 3,48<\/td><td>4,87 \/ 4,26 \/ 3,79<\/td><\/tr><tr><td colspan=\"2\">Water flow (High \/ Medium \/ Low)<\/td><td>m 3 \/h<\/td><td>0,48 \/ 0,46 \/ 0,42<\/td><td>0,67 \/ 0,57 \/ 0,51<\/td><td>0,77 \/ 0,68 \/ 0,61<\/td><td>0,85 \/ 0,72 \/ 0,65<\/td><\/tr><tr><td colspan=\"2\">Pressure drop (High \/ Medium \/ Low)<\/td><td>kPa<\/td><td>31,61 \/ 28,63 \/ 25,36<\/td><td>56,75 \/ 41,23 \/ 33,02<\/td><td>41,17 \/ 33,54 \/ 27,05<\/td><td>50,68 \/ 39,47 \/ 33,66<\/td><\/tr><tr><td colspan=\"2\">Consumption (High \/ Medium \/ Low)<\/td><td>W<\/td><td>13 \/ 11 \/ 10<\/td><td>34 \/ 22 \/ 15<\/td><td>26 \/ 18 \/ 13<\/td><td>38 \/ 26 \/ 18<\/td><\/tr><tr><td rowspan=\"8\">Heating<\/td><td rowspan=\"4\">45\u00baC (2)<\/td><td>Capacity (High \/ Medium \/ Low)<\/td><td>kW<\/td><td>3,02 \/ 2,85 \/ 2,35<\/td><td>4,3 \/ 3,65 \/ 3,09<\/td><td>4,84 \/ 4,23 \/ 3,62<\/td><td>5,26 \/ 4,68 \/ 3,96<\/td><\/tr><tr><td>Water flow (High \/ Medium \/ Low)<\/td><td>m 3 \/h<\/td><td>0,51 \/ 0,49 \/ 0,46<\/td><td>0,73 \/ 0,64 \/ 0,56<\/td><td>0,84 \/ 0,73 \/ 0,64<\/td><td>0,89 \/ 0,80 \/ 0,68<\/td><\/tr><tr><td>Pressure drop (High \/ Medium \/ Low)<\/td><td>kPa<\/td><td>32,66 \/ 34,89 \/ 30,24<\/td><td>51,86 \/ 47,53 \/ 35,69<\/td><td>36,82 \/ 33,83 \/ 26,26<\/td><td>47,12 \/ 42,75 \/ 32,95<\/td><\/tr><tr><td>Consumption (High \/ Medium \/ Low)<\/td><td>W<\/td><td>11 \/ 11 \/ 9<\/td><td>31 \/ 20 \/ 14<\/td><td>22 \/ 16 \/ 12<\/td><td>33 \/ 23 \/ 16<\/td><\/tr><tr><td rowspan=\"4\">50\u00baC (3)<\/td><td>Capacity (High \/ Medium \/ Low)<\/td><td>kW<\/td><td>3,29 \/ 3,03\/ 2,63<\/td><td>5,08 \/ 4,33 \/ 3,77<\/td><td>5,68 \/ 4,94 \/ 4,24<\/td><td>6,31 \/ 5,57 \/ 4,77<\/td><\/tr><tr><td>Water flow (High \/ Medium \/ Low)<\/td><td>m 3 \/h<\/td><td>0,48 \/ 0,46 \/ 0,42<\/td><td>0,67 \/ 0,57 \/ 0,51<\/td><td>0,77 \/ 0,68 \/ 0,61<\/td><td>0,85 \/ 0,72 \/ 0,65<\/td><\/tr><tr><td>Pressure drop (High \/ Medium \/ Low)<\/td><td>kPa<\/td><td>37,49 \/ 30,25 \/ 26,53<\/td><td>61,94 \/ 37,88 \/ 30,34<\/td><td>43,74 \/ 29,69 \/ 23,98<\/td><td>51,65 \/ 36,3 \/ 30,3<\/td><\/tr><tr><td>Consumption (High \/ Medium \/ Low)<\/td><td>W<\/td><td>12 \/ 10 \/ 8<\/td><td>31 \/ 20 \/ 14<\/td><td>23 \/ 16 \/ 12<\/td><td>33 \/ 23 \/ 16<\/td><\/tr><tr><td colspan=\"3\">Air flow (High \/ Medium \/ Low)<\/td><td>m 3 \/h<\/td><td>492 \/ 454 \/ 400<\/td><td>825 \/ 869 \/ 590<\/td><td>862 \/ 741 \/ 634<\/td><td>979 \/ 849 \/ 717<\/td><\/tr><tr><td colspan=\"3\">Heat exchanger water volume<\/td><td>L<\/td><td>0.733<\/td><td>0.733<\/td><td>1.027<\/td><td>1.027<\/td><\/tr><tr><td colspan=\"3\">Power supply<\/td><td>V \/ F \/ Hz<\/td><td>220-240 \/ 1 \/ 50<\/td><td>220-240 \/ 1 \/ 50<\/td><td>220-240 \/ 1 \/ 50<\/td><td>220-240 \/ 1 \/ 50<\/td><\/tr><tr><td colspan=\"3\">Sound pressure (High \/ Medium \/ Low) (4)<\/td><td>dB(A)<\/td><td>32 \/ 30 \/ 27<\/td><td>45 \/ 39 \/ 35<\/td><td>38 \/ 34 \/ 30<\/td><td>44 \/ 40 \/ 35<\/td><\/tr><tr><td colspan=\"3\">Max. operating pressure<\/td><td>MPa<\/td><td>1.6<\/td><td>1.6<\/td><td>1.6<\/td><td>1.6<\/td><\/tr><tr><td colspan=\"3\">Water connections<\/td><td>inch<\/td><td>3\/4&#8243;<\/td><td>3\/4&#8243;<\/td><td>3\/4&#8243;<\/td><td>3\/4&#8243;<\/td><\/tr><tr><td colspan=\"3\">Drain connection<\/td><td>mm<\/td><td>\u03a620<\/td><td>\u03a620<\/td><td>\u03a620<\/td><td>\u03a620<\/td><\/tr><tr><td colspan=\"3\">Dimensions (Width x Height x Depth)<\/td><td>mm<\/td><td>915 \u00d7 290 \u00d7 233<\/td><td>915 \u00d7 290 \u00d7 233<\/td><td>1072 \u00d7 315 \u00d7 237<\/td><td>1072 \u00d7 315 \u00d7 237<\/td><\/tr><tr><td colspan=\"3\">Weight<\/td><td>kg<\/td><td>12.7<\/td><td>12.7<\/td><td>15.1<\/td><td>14.9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Notes:<\/strong><\/p>\n\n<p>(1) Cooling capacity for each of the 3 air flows and according to conditions: Water inlet\/outlet temp. 7\/12\u00baC, Ambient temp. 27\u00baC DB, 19\u00baC WB.  <br\/>(2) Heating capacity for each of the 3 air flows and according to conditions: Water inlet\/outlet temp. 45\/40\u00baC, Ambient temp. 20\u00baC.  <br\/>(3) Heating capacity for each of the 3 air flows and according to conditions: Water inlet temp. 50\u00baC, Ambient temp. 20\u00baC (for other temperatures see the<br\/>technical manual).<br\/>(4) Sound pressure level measured in a reverberation chamber, 1m away from the equipment both horizontally and vertically.<br\/>\u2013 The design and specifications are subject to change without prior notice for product improvement.  <\/p>\n","protected":false},"excerpt":{"rendered":"<p>MUP-W9 Series Wall Fan Coil Unit TECHNICAL SPECIFICATIONS Model MUP-09-W9 MUP-12-W9 MUP-16-W9 MUP-18-W9 Code CL04325 CL04326 CL04327 CL04328 Cooling (1) Capacity (High \/ Medium \/ Low) kW 2,7 \/ 2,59 \/ 2,39 3,81 \/ 3,3 \/ 2,88 4,47 \/ 3,98 \/ 3,48 4,87 \/ 4,26 \/ 3,79 Water flow (High \/ Medium \/ Low) m [&hellip;]<\/p>\n","protected":false},"featured_media":40851,"parent":0,"menu_order":0,"template":"","categoria-productos":[151,111],"etiqueta_producto":[],"class_list":["post-42430","gama","type-gama","status-publish","has-post-thumbnail","hentry","categoria-productos-chillers-and-fan-coils","categoria-productos-industrial-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/42430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama"}],"about":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/types\/gama"}],"version-history":[{"count":1,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/42430\/revisions"}],"predecessor-version":[{"id":42431,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/gama\/42430\/revisions\/42431"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media\/40851"}],"wp:attachment":[{"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/media?parent=42430"}],"wp:term":[{"taxonomy":"categoria-productos","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/categoria-productos?post=42430"},{"taxonomy":"etiqueta_producto","embeddable":true,"href":"https:\/\/www.mundoclima.com\/en\/wp-json\/wp\/v2\/etiqueta_producto?post=42430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}